DM-01 Converter designed for Fuel Flow Meters with pulse interface systems, which can be connected to the equipment of industrial automation.
Fuel Flow Meter connects to the pulse input of Converter DM-01.
Converter DM-01 processes pulse signal from Fuel Flow Meter and generates in its registers information about Quantity of pulses, average fuel consumption, instantaneous fuel consumption, fuel used, engine determined modes, engine hours and other parameters.
DM-01 Convertor is compatible with any meters, for instance, see Fuel flow meter with pulse interface.
Information that is stored in the registers of the Converter DM-01 can be received using the protocol MODBUS via RS485. (see DM-01.Communication protocol.pdf).
Parameter | Value |
---|---|
Supply voltage, Volts | 10…40 |
Power consumption, Watts | max 3 |
Voltage protection, Volts | 70 |
Operating temperature, grad Celsius | -40 … +85oC |
Relative humidity at ambient temperature 40 °С, % | 95 |
Pulse input, count | 1 |
Communication port | RS-485 (MODBUS) |
Dimensions (LxWxH), mm | 92 х 53.3 х 57.7 |
Weight, kg | 0.150 |
Item's Name | Quantity, pcs |
---|---|
DFM To MODBUS CONVERTOR DM-01 | 1 |
Mounting Kit DM-01 | 1 |
Documentation | 1 |
Carton package box | 1 |
Leds | Description | ||
---|---|---|---|
Name | Color | Mode | |
PWR/IN | Green | Off | Power off |
Blink 1 per 2 seconds |
Normal work DM-01. Input signal is not detected. |
||
Blink 2 per second |
Normal work DM-01. Input signal is detected. |
||
SYS/ERR | Red | On | An error is detected |
Blink 1 per 2 seconds |
Communication packet is received. | ||
Blink 2 per seconds |
Firmware update. |